what is the difference between IPX9 & IPX9K Ratings?
From: BONAD  Date: 2024-03-13 10:24:15


What does it mean of the IPX and IPX9K?

K" refers to the test band pressurisation requirements, IPX9K test pressure needs to reach 10,000Kpa, and then extended to other levels of protection with K, such as 4K, 6K, in fact, all have pressure requirements.

IPX9 and IPX9K are both standard IP enclosure waterproof grade, both of them meet the requirements of international standards ISO20653-2013, VW80000, Article 14.2.9 in GB/T4208-2017 and Fig. 7, Fig. 8, Fig. 9, Fig. 10, Fig. 11, Fig. 12 waterproof grade IPX9/9K. Among them, IPX9 is without increased pressure, while IPX9K is high temperature and high pressure spray test.

Degrees of protection against water

Table 4 contains short descriptions of the degrees of protection with the relevant requirements.

The degrees of protection 1 to 6K for the protection against water always include the preceding degrees of protection. Due to different physical effects, this does not apply automatically for the degrees of protection against water 7. 8 and 9K.

Should this apply nevertheless, the included lower degree of protection shall be indicated separately, e.g.IPX4K/IPX7.IPX5/IPX7.IPX6K/PX8 or IPX6K//IPX9K.

Degrees of protection against water

Second code element

Degree of protection

Brief description

Requirements

0

Not protected

None

1

Water drips vertically

Vertical drips shall not have any harmful effects or impair performance.

2

Water drips with enclosure inclined by 15°

Vertical drips shall not have any harmful effects or impair performance when the enclosure is tilted at any angle up to 15° on either side of the vertical.

3

Water spray

Water spray at an angle up to 60° on either side of the vertical shall have no harmful effects or impair performance.

4

Splash water

Water which splashes against the enclosure from any direction shall not have any harmful effects or impair performance.

4K

Splash water with increased pressure

Water which splashes against the enclosure from any direction with increased pressure shall not have any harmful effects or impair performance.

5

High-velocity water

Water which is directed against the enclosure from any direction as a jet shall not have any harmful effects or impair performance.

6

Strong high-velocity water

Water which is directed against the enclosure from any direction as a strong jet shall not have any harmful effects or impair performance.

6K

Strong high-velocity water with increased pressure

Water which is directed against the enclosure from any direction as a strong jet with increased pressure shall not have any harmful effects or impair performance.

7

Temporary immersion in water

Water shall not penetrate in a quantity causing harmful effects or impair performance if the enclosure is immersed in water temporarily under specified pressure and time conditions.

8

Continuous immersion in water

Water shall not penetrate in a quantity causing harmful effects if the enclosure is continuously immersed in water under conditions which shall be agreed between supplier and car manufacturer, but which are more severe than code 7.

9K

Water during high-pressure/steam-jet cleaning

Water which is directed against the enclosure from any direction shall not have any harmful effects or impair performance.


IPX9 AND IPX9K RATINGS – MEANING AND TESTING CONDITIONS

As explained in the introduction, IPX9 and IPX9K ratings guarantee protection against high-pressure, high-temperature water jets. The testing conditions for IPX9 and IPX9K ratings are precisely defined by the IEC and ISO.

When small devices are tested, they are put on a rotating stand inside a testing chamber. The rotation speed is 5rpm. For large devices, the IEC standard allows tests in an open space (outside the testing chamber).

For both standards, the water temperature is set at 80°C (±5°C). The distance between the device and the spray nozzle is 100-150mm. For large enclosures, the IEC allows a distance of 175mm ±25mm.

Small devices are sprayed from 4 positions/angles (0°-30°-60°-90°), measured from the horizontal axis. Large devices are sprayed from all angles.

Water pressure is 8-10 MPa, and the volume is 15 l/min.

The test duration is 30sec per position for small devices or 1min per m2 for large devices. The minimal test duration for large devices is 3 minutes.

IPX9 and IPX9K Testing Conditions

Testing Conditions

IPX9

IPX9

IPX9K

Small Enclosures

Large Enclosures

Water Temperature

80°C (± 5°C)

80°C (± 5°C)

80°C (± 5 °C)

Distance

100-150mm

175mm ± 25mm

100-150mm

Angle

0°/30°/60°/90°

All directions

0°/30°/60°/90°

Turntable Speed

5rpm (± 1rpm)

N/A

5rpm (± 1rpm)

Water Pressure

8-10 MPa

8-10 MPa

8,000-10,000 kPa

Water Flow Rate

15 l/min (± 1 l/min)

15 l/min (± 1 l/min)

14-16 l/min

Test Duration

30sec per position

1 min per m2 (at least 3min)

30sec per position

The marking of an enclosure with the Ip code IPX34K means:

[IPX3] Protection of the electrical equipment access to the enclosure against foreign objects with adiameter of more than 2,5 mm (protection against foreign objects), and protection of persons handling rods of 2,5 mm diameter or more against access within the enclosure(protection against access).

(IPX4K) Protection of electrical equipment within the enclosure against harmful effects resulting from water splashing against the enclosure with increased pressure from any direction (pro-tection against water)

The marking of an enclosure with the lP code lP16KB means:

(IPX1)Protection ofthe electrical equipment within the enclosure against foreign objects with adiameter of more than 50 mm(protection against foreign objects).

(IPX6K) Protection of electrical equipment within the enclosure against harmful effects resulting from water directed against the enclosure from any direction as a strong jet with increased pressure(protection against water).

Protection of persons against finger contact with hazardous parts within the enclosure (pro-tection against access).


 
 
Home  |  Products  |  News  |  About us  |  Feedback  |  Contact us  |  
Copyright © 2008-2015 Hong Kong Bonad Technology Limited | Shenzhen Bonad Instrument Co., LTD. All Rights Reserved.
 
    Add:C505, Hongdu Building,Bao\\\'an45 district,Shenzhen,518101,Guangdong Province,China    Tel:+86-13380391156    Fax:0755-23721200    Email:Alice@szbonad.com
 
黄色片在线观看| 久久久久精品国产三级蜜奴| 99福利视频一区二区三区| 日日噜噜噜夜夜爽爽狠狠视频| 日产乱码卡一卡2卡三卡四颐和园| 人人妻人人爽人人做夜欢视频| 96国产XXXX免费视频| 最近手机中文字幕| 国模冰莲极品自慰人体| 男女啪啪高清无遮挡免费| 欧美熟妇hairy高潮hd| 久久精品国产一区二区| 黑人狂桶女人高潮嗷嗷叫小说| 麻花传媒MV国产免费观看视频| 自拍性旺盛老熟女| 热99re久久精品这里都是精品免费| 国产成人无码手机在线观看| 民和| 人妖视频| 国产精品性| 短裙高铁车厢被强好爽h| 亚洲婷婷在线| 超爱碰在线资源| 久久亚洲av午夜福利精品一区| 欧美一级日韩一级| 老汉色av影院| 精品乱码| 精品欧美黑人一区二区三区 | 国产精品不卡无码AV在线播放| 亚洲av成人影视综合网| 无码内射中文字幕岛国片| 黄平县| 人妻秘书痴汉电车| 蜜臀av性久久久久蜜臀aⅴ麻豆| 国产l精品国产亚洲区| 人妻中文字幕乱人伦在线| 亚洲AV色男人的天堂 | 国产在线无码av完整版在线观看| 股票| 好大好湿好硬顶到了好爽| 色av人人澡人人爽人人夜夜学生|